Digital LCD PH Meter Pen
Digital PH Meter Water Test is Suitable for Aquarium, Swimming Pool, Indoor Outdoor
Specifications:
► Measuring range: 0.00-14.00 pH
► Resolution: 0.01 pH
► Accuracy: 0.01 pH
► Batteries: 2X 1.5V LR44 (not included)
► Automatic temperature compensation: 0-50Centigrade(32-122It)
► Dimensions: 15×2.5×1.3cm/6×1.1×0.5 inch
► Net Weight: 52g/1.83 oz
Warm tips
It STEP 1: Turn open pH meter, Clean the electrode in distill water
It STEP 2: Immerse the electrode in pH 6.86 standard buffer solution
It STEP 3: Press the « CAL » button. Wait until the display digital is 6.86pH and steady
It STEP 4: Clean the electrode in distill water and dry it, immerse the electrode in Ph 4.00 standard buffer solution
It STEP 5: Press the « CAL » button. Wait until the display digital is 4.00pH. Then complete pH 4.00 calibration
It STEP 6: Clean electrode and dry it, put the meter into PH 9.18 standard buffer solution. Check if reading is correct between 9.17-9.19pH
Package Includes:
► 1 x PH Meter
► 2 x Calibration packets
► 1 x User`s manual
Note:
It Clean the electrode with distilled water every time before and after use
It Be careful with the glass probe since it may be a little fragile when you use.
It Remember to gently wipe it with a clean, soft cloth when you`re done before capping it again.
It Open the battery case or replace battery, then need to recalibrate the meter
4 000 CFA
4 en stock
UGS : WEMOS2636
Catégorie : Electronic equipment
Description
Digital PH Meter Water Test is Suitable for Aquarium, Swimming Pool, Indoor Outdoor
Specifications:
► Measuring range: 0.00-14.00 pH
► Resolution: 0.01 pH
► Accuracy: 0.01 pH
► Batteries: 2X 1.5V LR44 (not included)
► Automatic temperature compensation: 0-50Centigrade(32-122It)
► Dimensions: 15×2.5×1.3cm/6×1.1×0.5 inch
► Net Weight: 52g/1.83 oz
Warm tips
It STEP 1: Turn open pH meter, Clean the electrode in distill water
It STEP 2: Immerse the electrode in pH 6.86 standard buffer solution
It STEP 3: Press the « CAL » button. Wait until the display digital is 6.86pH and steady
It STEP 4: Clean the electrode in distill water and dry it, immerse the electrode in Ph 4.00 standard buffer solution
It STEP 5: Press the « CAL » button. Wait until the display digital is 4.00pH. Then complete pH 4.00 calibration
It STEP 6: Clean electrode and dry it, put the meter into PH 9.18 standard buffer solution. Check if reading is correct between 9.17-9.19pH
Package Includes:
► 1 x PH Meter
► 2 x Calibration packets
► 1 x User`s manual
Note:
It Clean the electrode with distilled water every time before and after use
It Be careful with the glass probe since it may be a little fragile when you use.
It Remember to gently wipe it with a clean, soft cloth when you`re done before capping it again.
It Open the battery case or replace battery, then need to recalibrate the meter